Product name:High precision residual chlorine analyzer TRC400
I. Product Overview
TRC400 high-precision residual chlorine analyzer, built-in Swiss high-precision sensors, designed for agricultural drinking water, waterworks and other industries, used for continuous monitoring of residual chlorine content in water solution. The instrument is characterized by high measurement accuracy, fast response time and low maintenance cost, making it an ideal choice for water quality safety.
TRC400 analyzer outputs one way (4~20) mA standard signal and one way RS485 signal, which can be easily connected to a variety of regulators, such as two-bit regulator, time-proportional regulator, non-linear regulator and classic PID regulator, etc., to meet the needs of diverse residual chlorine control system.
Residual chlorine analyzer technical parameters
Residual chlorine meter TRC400 technical parameters:
Display:
| 7-inch touch screen
|
Protection box size:
| external dimensions 400mm × 300mm × 180mm, window size 155mm × 87mm
|
Measuring range:
| residual chlorine (05) mg / L, temperature (0.140.0)℃
|
Transmission output:
| (4~20) mA (optional)
|
Communication output:
| MODBUS RS485 communication function
|
Load resistance:
| ≤750Ω
|
Ambient humidity:
| ≤95% no condensation
|
Power supply:
| 220VAC
|
Protection grade:
| IP43
|
Residual chlorine electrode ERC400 technical parameters:
Measurement content:
| HCLO, CLO2
|
Measuring system:
| microelectronic MEMS technology, special membrane structure
|
Measuring range:
| (0~5) mg/L
|
Measurement accuracy:
| Absolute error ±0.01mg/L (0~0.1mg/L); ±5% of the measured value or ±0.03mg/L (take the larger value) (0.1~2mg/L); ±5% of the measured value or ±0.25mg/L (take the larger value) (2~5mg/L)
|
Resolution:
| 0.01
|
Polarization time:
| first use, first water for 2 hours, then power for half an hour
|
Response time:
| less than 30 seconds after polarization is completed
|
Minimum conductivity:
| ≥100uS/cm
|
Working temperature:
| (0~40)℃ (non-condensing)
|
Temperature compensation:
| Pt1000, built-in integrated automatic compensation
|
Maximum pressure:
| 4bar
|
Recommended flow rate:
| ≥0.03m/s (in flow cell)
|
pH range:
| (5~9) pH
|
Maximum chlorine concentration:
| ≥5ppm
|
Supply voltage:
| Standard 24V DC±2V; optional 12V DC±2V
|
Power consumption:
| about 1.56W
|
Digital communication:
| MODBUS RS485 communication function
|
Cable length:
| standard 3 meters, can be customized
|
Probe weight:
| about 210g
|
Thread size:
| NPT 3/4
|
Connection:
| 5-pole waterproof aviation plug
|
Moisture-proof material:
| PVC and Viton® O-ring sealing
|
External dimensions (unit: mm)
|
|
Second, the residual chlorine analyzer TRC400 core features
High-precision sensor: the original Swiss imported sensor is used to ensure accurate and reliable measurement.
Fast response: response time is less than 30 seconds after polarization is completed, real-time monitoring of water quality changes.
Multiple output signals: (4~20) mA analog output and RS485 communication output to meet a variety of control needs.
7-inch touch screen: intuitive display of measured values, temperature, current and other information, easy to operate.
Low maintenance cost: reasonable design, simple maintenance, reduce the cost of use.
Third, electrode use requirements
In order to ensure the measurement accuracy of TRC400 analyzer, please follow the following electrode use requirements:
When energized, the electrode must be placed in water to prevent damage.
Before first use or re-use after drying, the electrode should be placed in flowing tap water for 12 hours without power on.
The recommended measurement flow rate is (12~30) L/h. Avoid use in sporadic water flow.
Use only a single disinfectant to avoid cross-sensitivity affecting the measurement results.
Electrode range is (0~5) mg/L, over range use will shorten the life of electrode.
The pH range of the measured liquid is 5~9, exceeding the range may damage the electrode.
After measurement, rinse the electrode with chlorine-free water for not less than 60 seconds and dry it for storage.
V. Fixed Installation
The TRC400 analyzer should be installed in a location that meets the following conditions:
Indoor installation is recommended to ensure a clean and dry environment.
No high-power motor-type operating equipment nearby to avoid interference.
The ambient temperature range is (0.1~40)℃ to ensure the normal operation of the instrument.
Sixth, the field of application
TRC400 high-precision residual chlorine analyzer is widely used in agricultural drinking water, waterworks and other industries, for continuous monitoring of residual chlorine content in the water solution, to ensure the safety of water quality, is the right hand in the field of water quality monitoring.
The above is a detailed introduction of this product, if you have any questions or need further information, please feel free to contact us.